+49 (0) 2335 68277-0

Pump Groups

Pump Groups without TDC Controller

 

S1 Solar 1

Completely pre-assembled and tested pump groups 3/4“ with solar pump and safety assembly

  • High-efficiency pump WILO Yonos Para ST 25/7 PWM
  • Ball valves with integrated stop valve and thermometer
  • Flow meter 2-12 l/min with stop valve and 2 fill and drain ball valves
  • Safety assembly with manometer 0-10 bar and safety valve 6 bar
  • Outlet 3/4“ to expansion tank at the safety assembly
  • Wall-fastening fixture
  • Working Temperature 120 °C (short-term 160 °C)
S1-Solar-1 3/4“AG
Art. Nr. 71111

S2-Solar2

Completely pre-assembled and tested pump groups with solar pump and safety assembly

  • High-efficiency pump WILO Yonos Para ST 25/7 PWM
  • Ball valves with integrated stop valve and thermometer
  • Flow meter 2-12 l/min with stop valve and 2 fill and drain ball valves
  • Safety assembly with manometer 0-10 bar and safety valve 6 bar
  • Outlet 3/4“ to expansion tank at the safety assembly
  • Wall-fastening fixture
  • Working Temperature 120 °C (short-term 160 °C)
S2-Solar-2 3/4“AG
Art. Nr. 72211

S2-Solar2

Completely pre-assembled and tested pump groups 3/4“ with solar pump and safety assembly

  • High-efficiency pump WILO Yonos Para ST 25/7 PWM or WILO Yonos Para ST 25/13 PWM
  • ball valves with integrated stop valve and thermometer
  • flow meter 2-12 l/min with stop valve and 2 fill and drain ball valves
  • Safety assembly with manometer 0-10 bar and safety valve 6 bar
  • Outlet 3/4“ to expansion tank at the safety assembly
  • Wall-fastening fixture
  • Distance between supply and return 125 mm
  • Working Temperature 120 °C (short-term 160 °C)
  • Vent pipe
S2-Solar-3 3/4“AG
Art. Nr. 72311

Pump Groups with TDC Controller

 

S1-Solar-10

Completely pre-assembled and tested single strand pump group 3/4“ with pump and safety assembly and solar controller STDC

  • High-efficiency solar pump WILO Yonos Para ST 25/7 PWM
  • Temperature Difference Controller STDC plugwired and tested, including 2 sensor probes
  • Ball valve with integrated non-return valve and thermometer
  • Flowmeter 2-12 l/min with shut-off and 2 fill and drain ball valves
  • Safety assembly with manometer 0-10 bar and safety valve 6 bar
  • Outlet 3/4“ to expansion tank at the safety assembly
  • Wall-fastening fixture
  • Working Temperature 120 °C (short-term 160 °C)
Art. Nr. 61103 – S1-Solar-10 Pumpengruppe 3/4“AG + STDC + HE Pumpe WILO Yonos Para ST 25/7 PWM
ab Menge 1/5/10/20

S2-Solar30

Completely pre-assembled and tested solar station 3/4“ with pump, safety assembly, breather tube and solar controller MTDC
or LTDC

  • High-efficiency solar pump WILO Yonos Para ST 25/7 PWM or WILO Yonos Para ST 25/13 PWM
  • Temperature Difference Controller MTDC or LTDC plugwired and tested sensors included
  • Ball valves with integrated stop valve and thermometer
  • Flowmeter 2-12 l/min with stop valve and 2 fill and drain valves
  • Safety assembly with manometer 0-10 bar and safety valve 6 bar
  • Outlet 3/4“ to expansion tank at the safety assembly
  • Wall-fastening fixture
  • Distance between supply and return 125 mm
  • Working Temperature 120 °C (short-term 160 °C)
Art. Nr. 63163 – S2-Solar-30 Pumpengruppe 3/4“AG + MTDC
+ HE Pumpe WILO Yonos Para ST 25/7 PWM
ab Menge 1/5/10/20
Art. Nr. 63263 – S2-Solar-30 Pumpengruppe 1“AG + MTDC
+ HE Pumpe WILO Yonos Para ST 25/13 PWM
ab Menge 1/5/10/20
Art. Nr. 63173 – S2-Solar-30 Pumpengruppe 3/4“AG + LTDC
+ HE Pumpe WILO Yonos Para ST 25/7 PWM
ab Menge 1/5/10/20
Art. Nr. 63273 – S2-Solar-30 Pumpengruppe 1“AG + LTDC
+ HE Pumpe WILO Yonos Para ST 25/13 PWM
ab Menge 1/5/10/20

Pump groups of different manufacturers and previous versions with standard pumps are available on request.