+49 (0) 2335 68277-0

°CALEONbox system and individual room controllers

Universal system and individual room controller in combination with °CALEON or °CALEON Clima room controllers.

CaleonBox

°CALEONbox

For surface heatings in combination with up to 8 °CALEON room controllers.

CaleonBox

°CALEONbox Clima

For surface heating and cooling in combination with up to 8 °CALEON Clima room controllers.

CaleonBox

°CALEONbox Friwa

For surface heating and fresh water systems in combination with up to 8 °CALEON room controllers

°CALEONbox °CALEONbox Clima °CALEONbox Friwa
Power supply 230VAC 230VAC 230VAC
Internal operating voltages 24VDC, 5VDC, 3.3VDC 24VDC, 5VDC, 3.3VDC 24VDC, 5VDC, 3.3VDC
Relay outputs 230VAC on/off 9 9 9
Relay outputs potential-free with switch contact 1 2 2
0-10V or PWM outputs 3 3 3
24VDC voltage output for external devices Yes, max. 6W Yes, max. 6W Yes, max. 6W
LEDs for operating conditions 13 14 14
Temperature sensor inputs *1 up to 20 up to 20 up to 20
Grundfos VFS Sensor input *4 1
Compatible room controllers *3 up to 8 °CALEON up to 8 °CALEON or °CALEON Clima up to 8 °CALEON or °CALEON Clima
Digital interface *2 2x CAN + 1-Wire 2x CAN + 1-Wire 2x CAN + 1-Wire
Heating pump *5 230VAC on/off or PWM 230VAC on/off or PWM 230VAC on/off or PWM
Heating mixer *6 0-10V or PWM 0-10V or PWM 0-10V or PWM
Heating zones and actuators *7 8 x 3 8 x 3 8 x 3
Heat request *8
Heating/cooling switching *8
Cooling request *8
Dehumidifiers *9
Heating operating times per day *10 8 per zone 8 per zone 8 per zone
Comfort function for rapid heating *10 ✓ for each zone ✓ for each zone ✓ for each zone
Energy-saving heating mode Eco *10 ✓ for each zone ✓ for each zone ✓ for each zone
Cooling times per day *10 8 per zone 8 per zone
Comfort function for rapid cooling *10 yes, for each zone yes, for each zone
Energie-saving cooling mode Eco *10 yes, for each zone yes, for each zone
Internet access via SOREL Connect *11
Dew point calculation *12
Holiday programme
PID control for constant room temperature
Frost protection function
Circulation pump operation

 

*1 by 1-wire bus up to 20 sensors. Additional temperature sensors by CAN network
*2 Two separate CAN networks, 1x private (appartment), 1x heating system (building)
*3 up to 8 °CALEON can be supplied with 24VDC by °CALEONbox. When connecting more °CALEONs, an additional power supply is required. Alternatively, an external 230VAC thermostat can be operated for each zone.
*4 for measuring tap temperature and flow for domestic hot water control
*5 via 230VAC relays on/off, or speed-controlled via PWM
*6 Flow temperature control is done according to room temperature, optionally weather-compensated or combination of weather-compensation with room temperature influence
*7up to 8 heating zones with up to 3x 230VAC actuators as NO or NC design also with PID control
*8 potential-free relay contact, 0-10V or PWM signal or via CAN network
*10 adjustable via °CALEON or °CALEON Clima
*11 via SOREL Data Logger (soon also via °CALEON 24VDC Smart Thermostat with Wifi)
*12 separately in every zone where °CALEON Clima is installed

No downloads found.

No downloads found.

No downloads found.

pcsimulation

PC Simulation

Virtual simulators of any SOREL controller are available free of charge for easy product trial, technical trainings or to facilitate your customer support.

Simu Anfragen
haendlersuche

Where to buy

Find your national SOREL contact person or the nearest SOREL retailer

Ansprechpartner finden

Durch die weitere Nutzung der Seite stimmen Sie der Verwendung von Cookies zu. Weitere Informationen

Die Cookie-Einstellungen auf dieser Website sind auf "Cookies zulassen" eingestellt, um das beste Surferlebnis zu ermöglichen. Wenn Sie diese Website ohne Änderung der Cookie-Einstellungen verwenden oder auf "Akzeptieren" klicken, erklären Sie sich damit einverstanden.

Schließen